Oceanic
Exploration
Feasibility Study for the East Timor Pipeline
|
|
The following values were calculated/assumed:
| Yearly
Consumption |
|
| East Timor
population |
820,000 |
| Capita per
year |
25 mmBtu (Philippines
22mmBtu) |
| Total mmBtu
per year |
20,500,000 |
| Gas (scf of
gas produces 1027Btu) |
19,960
mmscf/year |
Preliminary calculations have
been conducted using the following pipeline parameters:
- Outside diameter 10inch
- Wall thickness
less than 25mm
Calculations show that a 10-inch
pipeline produces over 24,000 mmscf/year of gas, which indicates that
this size may be sufficient to provide the domestic market.
6.1 CONCLUSIONS
- A 28-inch pipeline to feed
into an LNG plant is potentially feasible.
- A 10-inch pipeline would
be adequate to supply the domestic market of East Timor.
W:\Oil&Gas\Joint
Ventures\Intec\Projects\Pw Perth projects\0063.01 Oceanic East Timor\P0063.01Rev
1-with changes.doc
Page 11 13 June 2002
NEXT
SLIDE
|